Syringe Pumps

Overview

Syringe Pump for dosing, chemical mixing, microdialysis, injections

Reliable, accurate, and programmable!

Reliable due to a simple, robust design, and solid construction. This pump will run for many years of trouble free use. Accurate due to the use of a brushless stepper motor, a finely threaded precision lead screw and a microelectronic controller. Programmable using either the front control panel or by connecting the syringe pump to a computer.

Our syringe pumps are perfect for:

  • Animal Dosing
  • Microdialysis
  • Microfluidics
  • Electrospray
  • Chemical Mixing

Example flow rates per syringe

(valid for SP1000 and SP500 pumps)

Syringe Size (cc)Maximum Rate (mL/hr)Minimum Rate (µL/hr)
0.5 µL25.490.001
153.090.73
3192.52.646
5406.15.581
106008.244
20975.813.41
30128217.63
60212029.13

Features

Features

  • Built for automation
  • Operates stand-alone (except SP500 series) or from a computer (except SP300 series)
  • Infusion (except SP300 series) and withdrawal by rate and/or volume
  • Programmable preset protocols
  • Program up to 41 pumping phases that change pumping rates, set dispensing volumes, insert pauses, control and respond to external signals, sound the buzzer
  • RS-232 and TTL logic control interfaces
  • Network, control, and monitor up to 100 pumps with one computer
  • Worldwide power supplies available
  • Motor stall detection, on most models
  • Dispensing accuracy of +/-1%
  • Unlimited lifetime technical support
  • One year warranty
dual syringe pumps for continuous pumping on a programmed schedule Not for clinical use on humans

The pumps are often used in dual-pump setups with check valves for continuous pumping so that one syringe dispenses while the other reloads. Please ask and we can provide the entire set up.

Models

Models

SP1000SP2200SP1600SP1800SP300SP500
Max Syringe Size60 ml60 ml60 ml10 ml60 ml60 ml
Min Syringe Size0.5 µl0.5 µl0.5 µl0.5 µl0.5 µl0.5 µl
Flow Rate (Max per syringe)2120 ml / hr7635 ml / hr1385 ml / hr392 ml / hr1516 ml / hr2120 ml / hr
Flow Rate (Min per syringe)0.001 µl/ hr0.001 µl/ hr0.001 µl/ hr0.001 µl/ hr0.001 µl/ hr0.001 µl/ hr
Dimensions (length x width x height, inches)8 ¾ x 5 ¾ x 4 ½ (22.9 x 14.6 x 11.4 cm)8 ¾ x 5 ¾ x 4 ½ (22.9 x 14.6 x 11.4 cm)10 ¼ x 15 x 5 (26.0 x 38.1 x 12.7 cm)10 ¼ x 15 x 5 (26.0 x 38.1 x 12.7 cm)8 ¾ x 5 ¾ x 4 ½ (22.9 x 14.6 x 11.4 cm)9 ½ x 4 ¼ x 4 ¼ (23.5 x 10.8 x 10.5 cm)
Maximum Pumping Force (lbs)35 @ min. speed, 15 @ max. speed100 @ min. speed, 15 @ max speed160 @ min. speed, 30 @ max speed160 @ min. speed, 30 @ max speed35 @ min. speed, 18 @ max speed35 @ min. speed, 15 @ max. speed
Stand-Alone?YesYesYesYesYesNo
Programmable?YesYesYesYesYesYes

SP1000 programmable syringe pump $995

  • Holds 1 Syringe up to 60 cc
  • Infusion rates from 0.001 µL/hr (0.5 ml syringe) to 2100 ml/hr (60 cc syringe)
  • Easy-to-use keypad interface
  • Space Saving Chassis: Foot print size of only 5 3/4″ x 8 3/4″
  • Very easy to set up, just enter the syringe diameter, dispense rate, dispense volume, and press start
  • Advanced functions and programming features
  • Motor stall detection
  • Reliable and accurate. Designed and manufactured in the USA.

SP1010 high force pump $1,100

SP100 Programmable Syringe Pump
  • with twice the force of the SP1000 and 3X the maximum speed!

Multi-Syringe Pumps

SP2200 programmable dual syringe pump $1,295

programmable dual syringe pump SP2200

  • Similar to SP1000 but holds 1 or 2 syringes of up to 60 cc each. The syringes can be different sizes (this model only).
  • Infusion rates from 0.001 µL/hr (0.5 ml syringe) to 7630 ml/hr (60 cc syringe)

SP1600 programmable 6-syringe pump $1,995

programmable multi-syringe pump for mixing, animal dosing, injecting and draining

  • Similar to SP1000 but holds 2, 4,
    or 6 syringes (same size) of up to 60 cc each.
  • Infusion rates from 0.001 µL/hr (0.5 µL syringe) to 1337 ml/hr (60 cc syringe)
  • Higher flow rate models available

SP1800 programmable 8-syringe pump $1,995

programmable multi-syringe pump for mixing, animal dosing, infusion and withdrawal

  • Similar to SP1000 but holds 2, 4, 6, or 8 syringes (same size) of up to 10 cc.
  • Infusion rates from 0.001 µL/hr (0.5 µL syringe) to 380 ml/hr (10 cc syringe)
  • Higher flow rate models available

SP1070-M programmable syringe pump for microfluidics $1,995

programmable microfluidics syringe pump for mixing, animal dosing, infusion and withdrawal

  • The smoothest microfluidic syringe pump on the market (advance per step: 4.252232 Nanometers)
  • Infusion rates from 8 pl/hr (0.5 µL syringe) to 2545 µl/min (140 cc syringe)
  • double syringe model available

SP300 “Just Infusion” Syringe Pump $350

syringe pump SP300 infusion or injection only
Just the features that you want, and none that you don’t want to pay for. Similar to the SP1000 with just the basic features. Does not withdraw, volume target, or have computer interface.
  • Holds small or big syringes up to 60 mL
  • Pump continuously until you stop the pump
  • Infusion rate can be changed while pumping
  • Remembers previous settings on power up
  • Power failure mode allows pump to continue pumping after a reset
  • Syringe purge mode
  • Displays total volume dispensed in mL or µL units
  • Maximum pumping rate of 1500 mL/hr with a 60 mL syringe
  • Minimum pumping rate of 0.001 µL/hr with a 0.5 µL syringe
  • Precise reproducible flow rates
  • Selectable infusion rates units: mL/hr, µL/hr, mL/min, µL/min

SP500 open housing model $725

syringe pump SP500 for accurate dispensing
Designed for OEM applications, this pump has the same mechanisms and electronics as the SP1000 aside from the front panel controls
  • Built for Automation
  • Operates from a computer
  • Infusion and withdrawal
  • Set a single pumping rate and/or dispensing volume
  • Program up to 41 pumping phases that change pumping rates, set dispensing volumes, insert pauses, control and respond to external signals, sound the buzzer
  • Network, control, and monitor up to 100 pumps with one computer
  • Computer controllable: networkable up to 100 pumps
  • Stand-alone operation: pre-program the pump with a dispensing program, then operate the pump from an attached Foot Switch, button, or I/O controller
  • Add the OEM Starter Kit to run as a fully functional, stand-alone pump
  • Motor stall detection available in NE-501 model ($600)
  • Dispensing accuracy of ± 1%
  • Unlimited lifetime technical support
  • Two year warranty

SP510 open housing high force pump $790

  • with twice the force of the SP500 and 3X the maximum speed!

Accessories

Syringe Pump Accessories

We offer a line of accessories that add additional functionality to your syringe pumps. If you are ordering a pump in the 500 series, you should also order an Starter Pack to allow it to be interfaced with a computer.

FAQs

Syringe Pump FAQs

For programming instructions, please visit the Programming page.

What size syringes can I use in the pump?

It is recommended that you use syringes 0.5µm to 60cc in size. The pump can hold a syringe up to 140 cc, but can only open up to about 120 cc lengthwise. The exception is the SP-1800, which can hold syringes up to 10cc.

What is the maximum rate of the pump?

 
ModelMaximum Rate
SP10002100 ml/hr with a 60 cc syringe
SP 10107635 ml/hr with a 60 cc syringe
SP 22007630 ml/hr with a 60 cc syringe
SP16001385 ml/hr with a 60 cc syringe
SP1800392 ml/hr with a 10 cc syringe
SP3001500 ml/hr with a 60 cc syringe
SP500 / SP5012100 ml/hr with a 60 cc syringe
SP510 / SP5117635 ml/hr with a 60 cc syringe
 

Can I use a glass syringe with the pump?

The pumps come equipped with a Guide Rod Collar Clamp for use with fragile syringes. When the clamp is set in place it will cause the pump to stall before any pressure can be put on the syringe.

Can I use the syringe pump for mixing two solutions together?

Yes. You can use pump that holds multiple syringes (SP2200, SP1600 or SP1800). An alternative is to use a dual pump program, where two pumps are operated simultaneously with a secondary pump mirroring the primary pump. For this function, accessory cable CBL-DUAL is required. Please note that for applications requiring high-precision pumping of two syringes in tandem (e.g., some microfluidics applications), a multi-syringe pump is recommended. Having multiple syringes under the control of a single motor ensures smoother flow.

Can I set up syringe pumps for continuous pumping?

Yes. You can use a reciprocating pump program so that two pumps can be used together to create a continuous infusion system. For these functions, accessory cable CBL-DUAL is required. This mode allows one pump to infuse as the other withdraws. In Reciprocating Pumps Mode, the secondary pump must be left in its default communications setting of Address Mode. See the documentation with CBL-DUAL for more detailed information.

Can I use a computer to program my pump?

Yes. Syringe Pumps can communicate with any computer or device with an RS-232 communications port. You can directly control one or more pumps from a computer, including setting the pumping rate, direction and volume. PUMPTERM is a free terminal emulator program that allows communications with the syringe pump. Click here to download free pump terminal emulator. Communications with computers requires the CBL-PC accessory cable. Note: The SP500 and the SP510 units come with the CBL-PC.

What else can I use to control my pump?

Using the TTL logic control interface on the pump, you can connect it to a foot switch to start, stop, or trigger the next phase on your syringe pump. While the pump is controlled by these sources, you can put the pump in “lockout” mode in order to prevent unauthorized or accidental changes to the settings. “Lockout” mode can be accessed by pressing the “Diameter” key while turning on power to the pump. “P-L.n” will be displayed. When “n”=1, it is on. For more information about using the Foot Switch (FTSW), see the Syringe Pump user manual.

What is the difference between the SP300 “Just Infusion” pump and the others? What functionalities does it not have?

The SP300 “Just Infusion” syringe pump can infuse, but it does not have the capability to withdraw. The SP300 also doesn’t have computer interface capabilities and you cannot program a set volume to be dispensed. The SP300 does have the ability to keep track of the volume dispensed.

×
×
This is a static CMS block edited from admin panel. You can insert any content here. ×
This is a static CMS block edited from admin panel. You can insert any content here. ×